4-20mA, 0.5-4.5V, 0-5V Pressure Sensor

Introduction:

ACE pressure sensor series are designed as a transmitter capsule, There are three function modules embeded in a 316L stainless steel housing.
1) Pressure module–Utilizing silicone oil to transfer pressure from the 316L stainless steel diaphragm to a MEMS pressrue die.
2) ASIC module–Amplification and temprature compensation for pressure siginal
3) EMC module–Protection for the whole electric circuit

4-20mA, 0.5-4.5V, 0-5V Pressure Sensor-Jiangsu IntelliBee Control Sensor Technology Co., Ltd

The transmitter capsules themselves are ideally suited for embeding in application-specific systems.
Various amplified output with 4~20mA, 0.5~4.5V, 0~5V are avaliable, Also digital output of I2C or SPI could be provided based on request.

Features:

* Sensor size with transmitter functions
* Pressure range: 0-10Kpa…7Mpa
* Total error band<0.50%(typical)
* Wild compensation temp.(-10~70℃)
* Side O-ring seal,no assembly stress
* Low cost
* Reverse polarity protection
* EMC functions

Dimensions:

4-20mA, 0.5-4.5V, 0-5V Pressure Sensor-Jiangsu IntelliBee Control Sensor Technology Co., Ltd

Technical Parameter:

Ambient Temperature: 25°C (unless otherwise specified)

Parameters Min. Typical Max.
Accuracy(%FS)
combined linearity, hysteresis and repeatability
≤10Kpa ±0.2 ±0.3
>10Kpa ±0.05 ±0.1
Output 0.5~4.5V(Ratiometric); 0-5V; 4-20mA
Zero output(%FS) -0.5 ±0.25 0.5
Full Scale output(%FS) -0.5 ±0.25 0.5
Temp. characters
Operation Temp.(℃) -40 125
Compensation Temp.(℃)1 ≤40Kpa 0 50
>40Kpa -10 70
Total error band(%FS)2 -0.75 ±0.5 0.75
Long term Stability
Zero (±%FS annual) 0.2
Span (±%FS annual) 0.1
Power supply(V) See ordering information
Insulation Resistance 50MΩ/250V
Frequency(Hz) 1K
Overpressure ≤4Mpa 2X
>4Mpa 1.5X
Pressure media Liquids and Gases compatible with 316L Stainless Steel
Life >107 Full range pressure

1. Compensation temp. -20~85℃ optional
2. Total error band: total output error including Zero, Span,non-linearity,temp.erorr within compensated temperature range
CE Compliance:
* EN55022 Emissions Class A&B
* IEC61000-4-2(ESD):8KV(air)/6KV(contact)
* IEC61000-4-3 Radiated, Radio-Frequency Electromagnetic Field Immunity (3V/m, 80MHZ~1GHZ)
* IEC61000-4-4 Electrial Fast Transient Immunity (1KV)
* IEC61000-4-5 Surge Immunity
For Voltage Output: EX+ to GND:±0.5KV/42Ω; L to Case: ±1KV/12Ω; GND to Out+: ±0.5KV/42Ω
For Current Output: EX+ to EX-:±0.5KV/42Ω; L to Case: ±1KV/12Ω
This item is not applied for digital output
* IEC61000-4-6 Immunity to Conducted Disturbances Induced by Radio Frequency Fields (150KHZ~80MHZ 3V Level)
* IEC61000-4-9 Pulse Magnetic Field Immunity (100A/m Peak)

Ordering Information:

Model Input/Output
ACE11 5V/0.5-4.5V(Ratiometric)
ACE12 8-30V/0-5V
ACE13 8-30V/4-20mA
ACE1X Special
Code Pressure Reference
G Vent Gauge Pressure
S Sealed Gage
A Absolute Pressure
Code Pressure Range Gauge Absolute
10K 0-10Kpa *
40K 0-40Kpa *
100K 0-100Kpa * *
200K 0-200Kpa * *
600K 0-600Kpa * *
1M 0-1Mpa * *
1.6M 0-1.6Mpa * *
2.5M 0-2.5Mpa * *
4M 0-4Mpa * *
7M 0-7Mpa * *
XX Special
Code Electrical Connection
1 Connect Pins
2 Ribbon Cable(90mm as default)
Example: X Special
ACE13 A 600K 1
4-20mA Absolute 0-600Kpa Pins Model:ACE13A-600K1
Spread the love

Please Enter Your Message


    en_USEnglish