{"id":815,"date":"2022-04-21T07:22:32","date_gmt":"2022-04-21T07:22:32","guid":{"rendered":"http:\/\/www.intellibee.net\/?p=815"},"modified":"2022-04-28T00:15:35","modified_gmt":"2022-04-28T00:15:35","slug":"ceramic-transducer","status":"publish","type":"post","link":"https:\/\/www.intellibee.net\/it\/ceramic-transducer.html","title":{"rendered":"M501-R-002-0-1-01-1 Trasduttore ceramico"},"content":{"rendered":"<h4>Introduzione:<\/h4>\n<p><a href=\"http:\/\/www.intellibee.net\/it\/\">M501-R-002-0-1-01-1 trasduttore di pressione in ceramica<\/a>\u00a0sono realizzati con base in ceramica e membrana affacciata e funzionano secondo il principio piezoresistivo.<br \/>\nIl ponte di Wheatstone \u00e8 serigrafato su un lato del diaframma ceramico a filo che \u00e8, a sua volta, incollato al corpo del sensore. Il ponte \u00e8 rivolto verso l&#039;interno dove \u00e8 ricavata una cavit\u00e0 e quindi il lato opposto del diaframma pu\u00f2 essere esposto direttamente al fluido da misurare.<br \/>\nA causa dell&#039;eccellente resistenza chimica della ceramica Al2O3 (gas aggressivi, la maggior parte dei solventi e acidi, ecc.), non \u00e8 normalmente richiesta alcuna protezione aggiuntiva. IL <a href=\"http:\/\/www.intellibee.net\/it\/ceramic-pressure-sensors.html\/\">trasduttore di pressione in ceramica<\/a>\u00a0sono compensati termicamente da resistori PTC regolabili al laser e l&#039;uso della ceramica garantisce un&#039;elevata linearit\u00e0 su tutto il campo di misura, riducendo al minimo gli effetti dell&#039;isteresi.<\/p>\n<h4>Caratteristiche:<\/h4>\n<p>* Robusto diaframma sensibile in ceramica<br \/>\n* Punto zero, calibrazione laser a fondo scala<br \/>\n* Eccellente resistenza alla corrosione e resistenza all&#039;usura<br \/>\n* Antiurto, antivibrante<br \/>\n* Alta precisione, alta stabilit\u00e0<br \/>\n* Ampio intervallo di temperature di esercizio<br \/>\n* Di piccola dimensione, facile da impacchettare<\/p>\n<h4>Dimensioni:<\/h4>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-816\" src=\"http:\/\/www.intellibee.net\/wp-content\/uploads\/2022\/04\/Ceramic-Transducer.jpg\" alt=\"M501-R-002-0-1-01-1 Ceramic Transducer\" width=\"1344\" height=\"451\" srcset=\"https:\/\/www.intellibee.net\/wp-content\/uploads\/2022\/04\/Ceramic-Transducer.jpg 1344w, https:\/\/www.intellibee.net\/wp-content\/uploads\/2022\/04\/Ceramic-Transducer-300x101.jpg 300w, https:\/\/www.intellibee.net\/wp-content\/uploads\/2022\/04\/Ceramic-Transducer-1024x344.jpg 1024w, https:\/\/www.intellibee.net\/wp-content\/uploads\/2022\/04\/Ceramic-Transducer-768x258.jpg 768w\" sizes=\"auto, (max-width: 1344px) 100vw, 1344px\" \/><\/p>\n<h4>Tecnico:<\/h4>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>Intervallo di pressione<\/td>\n<td>100KPa~60MPa<\/td>\n<\/tr>\n<tr>\n<td>Dimensione<\/td>\n<td>\u03c618 \u00d7 5,25 mm<\/td>\n<\/tr>\n<tr>\n<td>Alimentazione elettrica<\/td>\n<td>5~ 30V CC<\/td>\n<\/tr>\n<tr>\n<td>Impedenza del ponte<\/td>\n<td>11K\u03a9\u00b120%<\/td>\n<\/tr>\n<tr>\n<td>Tempo di risposta<\/td>\n<td>&lt; 1ms<\/td>\n<\/tr>\n<tr>\n<td>Precisione (lineare, isteresi, ripetibilit\u00e0)<\/td>\n<td>0,2~0,4FS%<\/td>\n<\/tr>\n<tr>\n<td>Deriva zero<\/td>\n<td>\u00b10,2 mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Resistenza di isolamento<\/td>\n<td>&gt;2 kv<\/td>\n<\/tr>\n<tr>\n<td>Uscita di fondo scala<\/td>\n<td>2,0 ~ 4,8 mV\/V<\/td>\n<\/tr>\n<tr>\n<td>temp. caratteristiche: (Intervallo compensazione temperatura: 0 ~ 70 \u00b0C)<\/td>\n<td>\u00b10,015%FS\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperatura di esercizio<\/td>\n<td>-40~125 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stabilit\u00e0<\/td>\n<td>&lt;0,2%FSO\/anno<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Ordinazione:<\/h4>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>Tipo<\/td>\n<td>Intervallo di pressione (bar)<\/td>\n<td>Sovraccarico (barra)<\/td>\n<td>Pressione di rottura (barra)<\/td>\n<td>Sensibilit\u00e0 (mV\/V)<\/td>\n<\/tr>\n<tr>\n<td>AC21C-0.5<\/td>\n<td>0\u20260,5<\/td>\n<td>1<\/td>\n<td>2<\/td>\n<td>1.5~2.4<\/td>\n<\/tr>\n<tr>\n<td>AC21C-1<\/td>\n<td>0\u20261<\/td>\n<td>2<\/td>\n<td>4<\/td>\n<td>2.0~3.5<\/td>\n<\/tr>\n<tr>\n<td>AC21C-2<\/td>\n<td>0\u20262<\/td>\n<td>4<\/td>\n<td>5<\/td>\n<td>2.0~4.0<\/td>\n<\/tr>\n<tr>\n<td>AC21C-5<\/td>\n<td>0\u20265<\/td>\n<td>10<\/td>\n<td>12<\/td>\n<td>2.4~4.5<\/td>\n<\/tr>\n<tr>\n<td>AC21C-10<\/td>\n<td>0\u202610<\/td>\n<td>20<\/td>\n<td>25<\/td>\n<td>3.6~6.0<\/td>\n<\/tr>\n<tr>\n<td>AC21C-20<\/td>\n<td>0\u202620<\/td>\n<td>40<\/td>\n<td>50<\/td>\n<td>2.4~4.0<\/td>\n<\/tr>\n<tr>\n<td>AC21C-50<\/td>\n<td>0\u202650<\/td>\n<td>100<\/td>\n<td>120<\/td>\n<td>4.0~6.5<\/td>\n<\/tr>\n<tr>\n<td>AC21C-100<\/td>\n<td>0\u2026100<\/td>\n<td>200<\/td>\n<td>250<\/td>\n<td>3.1~4.8<\/td>\n<\/tr>\n<tr>\n<td>AC21C-200<\/td>\n<td>0\u2026200<\/td>\n<td>400<\/td>\n<td>500<\/td>\n<td>2.5~3.9<\/td>\n<\/tr>\n<tr>\n<td>AC21C-400<\/td>\n<td>0\u2026400<\/td>\n<td>650<\/td>\n<td>650<\/td>\n<td>3.1~4.8<\/td>\n<\/tr>\n<tr>\n<td>AC21C-600<\/td>\n<td>0\u2026600<\/td>\n<td>880<\/td>\n<td>880<\/td>\n<td>3.1~4.8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Nota:<br \/>\n1. Diversi lotti di prodotti possono avere colori di stampa diversi.<br \/>\n2. Pu\u00f2 essere utilizzato per il down-range e l&#039;ampiezza \u00e8 controllata entro \u00b150%FS.<br \/>\n3. La pressione massima del sistema deve essere inferiore al limite di protezione da sovraccarico del sensore, altrimenti influir\u00e0 sulla durata del prodotto e dannegger\u00e0 il prodotto.<br \/>\n4. Non forzare per tirare i perni oi cavi dei componenti sensibili.<br \/>\n5. Proteggere il diaframma di isolamento all&#039;estremit\u00e0 anteriore del componente sensibile alla pressione per evitare che l&#039;impatto del componente sensibile alla pressione danneggi il componente sensibile.<br \/>\n6. Se hai requisiti speciali sui parametri e le funzioni delle prestazioni del prodotto, ti preghiamo di contattarci.<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction: M501-R-002-0-1-01-1 ceramic pressure transducer\u00a0are made with a ceramic base plate and a flush diaphragm and work following the piezoresistive principle. The Wheatstone bridge is screen printed on one side of the flush ceramic diaphragm which is, in turn, glued to the sensor\u2019s body. The bridge faces the inside where a cavity is made and the diaphragm\u2019s opposite side can therefore be exposed directly to the medium to be measured. Because of the Al2O3 ceramic excellent chemical resistance (aggressive gases, most of solvents and acids, etc.), no additional protection is normally required. The ceramic pressure transducer\u00a0are thermally compensated by laser-adjustable PTC resistors and the use of ceramic ensures a high linearity across the entire range of measurement, reducing effects of hysteresis to a minimum. Features: * Sturdy ceramic sensitive diaphragm * Zero point, full-scale laser calibration * Excellent corrosion resistance and wear resistance * Anti-impact, anti-vibration * High precision, high stability * Wide operating temperature range * Small size, easy to package Dimensions: Technical: Pressure range 100KPa ~60MPa Dimension \u03c618\u00d75.25mm Power supply 5~ 30V DC Bridge impedance 11K\u03a9\u00b120% Response time &lt; 1mS Accuracy (linear, hysteresis, repeatability) 0.2 ~ 0.4 FS% Zero drift \u00b10.2mV\/V Insulation resistance &gt;2kv Output of full scale&#8230; <\/p>","protected":false},"author":1,"featured_media":818,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[20],"tags":[],"class_list":["post-815","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-other-pressure-sensor"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>M501-R-002-0-1-01-1 Ceramic Transducer | IntelliBee Sensor<\/title>\n<meta name=\"description\" content=\"M501-R-002-0-1-01-1 ceramic pressure transducer\u00a0are made with a ceramic base plate and work following the piezoresistive principle.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.intellibee.net\/it\/ceramic-transducer.html\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"M501-R-002-0-1-01-1 Ceramic Transducer | IntelliBee Sensor\" \/>\n<meta property=\"og:description\" content=\"M501-R-002-0-1-01-1 ceramic pressure transducer\u00a0are made with a ceramic base plate and work following the piezoresistive principle.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.intellibee.net\/it\/ceramic-transducer.html\/\" \/>\n<meta property=\"og:site_name\" content=\"Jiangsu IntelliBee Control Sensor\u00a0Technology Co., Ltd\" \/>\n<meta property=\"article:published_time\" content=\"2022-04-21T07:22:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-04-28T00:15:35+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.intellibee.net\/wp-content\/uploads\/2022\/04\/Ceramic-Sensor.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"intellibee\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"intellibee\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.intellibee.net\/ceramic-transducer.html\",\"url\":\"https:\/\/www.intellibee.net\/ceramic-transducer.html\",\"name\":\"M501-R-002-0-1-01-1 Ceramic Transducer | IntelliBee Sensor\",\"isPartOf\":{\"@id\":\"https:\/\/www.intellibee.net\/#website\"},\"datePublished\":\"2022-04-21T07:22:32+00:00\",\"dateModified\":\"2022-04-28T00:15:35+00:00\",\"author\":{\"@id\":\"https:\/\/www.intellibee.net\/#\/schema\/person\/10ea46db171f1101ea7bed15b9dfb7b2\"},\"description\":\"M501-R-002-0-1-01-1 ceramic pressure transducer\u00a0are made with a ceramic base plate and work following the piezoresistive principle.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.intellibee.net\/ceramic-transducer.html#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.intellibee.net\/ceramic-transducer.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.intellibee.net\/ceramic-transducer.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/www.intellibee.net\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"M501-R-002-0-1-01-1 Ceramic Transducer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.intellibee.net\/#website\",\"url\":\"https:\/\/www.intellibee.net\/\",\"name\":\"Jiangsu IntelliBee Control Sensor\u00a0Technology Co., Ltd\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.intellibee.net\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.intellibee.net\/#\/schema\/person\/10ea46db171f1101ea7bed15b9dfb7b2\",\"name\":\"intellibee\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/www.intellibee.net\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ed5b96990d921d06a75020a0c751675f05fdc03b69e76b2be7bdb378abdd8300?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ed5b96990d921d06a75020a0c751675f05fdc03b69e76b2be7bdb378abdd8300?s=96&d=mm&r=g\",\"caption\":\"intellibee\"},\"sameAs\":[\"http:\/\/ska.de5.myftpupload.com\"],\"url\":\"https:\/\/www.intellibee.net\/it\/author\/intellibee\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"M501-R-002-0-1-01-1 Ceramic Transducer | IntelliBee Sensor","description":"M501-R-002-0-1-01-1 ceramic pressure transducer\u00a0are made with a ceramic base plate and work following the piezoresistive principle.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.intellibee.net\/it\/ceramic-transducer.html\/","og_locale":"it_IT","og_type":"article","og_title":"M501-R-002-0-1-01-1 Ceramic Transducer | IntelliBee Sensor","og_description":"M501-R-002-0-1-01-1 ceramic pressure transducer\u00a0are made with a ceramic base plate and work following the piezoresistive principle.","og_url":"https:\/\/www.intellibee.net\/it\/ceramic-transducer.html\/","og_site_name":"Jiangsu IntelliBee Control Sensor\u00a0Technology Co., Ltd","article_published_time":"2022-04-21T07:22:32+00:00","article_modified_time":"2022-04-28T00:15:35+00:00","og_image":[{"width":700,"height":700,"url":"http:\/\/www.intellibee.net\/wp-content\/uploads\/2022\/04\/Ceramic-Sensor.jpg","type":"image\/jpeg"}],"author":"intellibee","twitter_card":"summary_large_image","twitter_misc":{"Written by":"intellibee","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.intellibee.net\/ceramic-transducer.html","url":"https:\/\/www.intellibee.net\/ceramic-transducer.html","name":"M501-R-002-0-1-01-1 Ceramic Transducer | IntelliBee Sensor","isPartOf":{"@id":"https:\/\/www.intellibee.net\/#website"},"datePublished":"2022-04-21T07:22:32+00:00","dateModified":"2022-04-28T00:15:35+00:00","author":{"@id":"https:\/\/www.intellibee.net\/#\/schema\/person\/10ea46db171f1101ea7bed15b9dfb7b2"},"description":"M501-R-002-0-1-01-1 ceramic pressure transducer\u00a0are made with a ceramic base plate and work following the piezoresistive principle.","breadcrumb":{"@id":"https:\/\/www.intellibee.net\/ceramic-transducer.html#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.intellibee.net\/ceramic-transducer.html"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.intellibee.net\/ceramic-transducer.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.intellibee.net\/"},{"@type":"ListItem","position":2,"name":"M501-R-002-0-1-01-1 Ceramic Transducer"}]},{"@type":"WebSite","@id":"https:\/\/www.intellibee.net\/#website","url":"https:\/\/www.intellibee.net\/","name":"Jiangsu IntelliBee Control Sensor\u00a0Technology Co., Ltd","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.intellibee.net\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"it-IT"},{"@type":"Person","@id":"https:\/\/www.intellibee.net\/#\/schema\/person\/10ea46db171f1101ea7bed15b9dfb7b2","name":"intellibee","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.intellibee.net\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ed5b96990d921d06a75020a0c751675f05fdc03b69e76b2be7bdb378abdd8300?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ed5b96990d921d06a75020a0c751675f05fdc03b69e76b2be7bdb378abdd8300?s=96&d=mm&r=g","caption":"intellibee"},"sameAs":["http:\/\/ska.de5.myftpupload.com"],"url":"https:\/\/www.intellibee.net\/it\/author\/intellibee"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/posts\/815","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/comments?post=815"}],"version-history":[{"count":3,"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/posts\/815\/revisions"}],"predecessor-version":[{"id":892,"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/posts\/815\/revisions\/892"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/media\/818"}],"wp:attachment":[{"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/media?parent=815"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/categories?post=815"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.intellibee.net\/it\/wp-json\/wp\/v2\/tags?post=815"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}