ACM1 microfused pressure sensor series based on microfused technology which employs micromachined silicon piezoresistive strain gages fused with high temperature glass to a stainless steel diaphragm.
The sensor body is machined from a solid piece of 17-4PH stainless steel, All welded structure without O-ring allowing a leak-proof.
All the key processes were operated in our 10,000 class cleaning room.
Each sensor was strictly temperature compensated for both zero and span. Various pressure ports are available; For maximum meeting customer’s needs, Special design will be provided if required.
* Standard output 0-100mV
* Welded structure without O-ring
* Medium / High pressure(0-3.5Mpa…100Mpa)
* 5X burst pressure
* Compatible with corrosive media
* Process control
* Pressure transmitters

Excitation:5VDC, 25℃
| Parameters | Min. | Typical | Max. | ||||
| Accuracy(%FS) | |||||||
| Non-Linearity1 | ±0.15 | ±0.25 | |||||
| Hysteresis | ±0.1 | ±0.15 | |||||
| Repeatability | ±0.1 | ±0.15 | |||||
| Output(mV) | |||||||
| Zero | -2 | ±1 | 2 | ||||
| Span(FS) | 97 | 100±1 | 103 | ||||
| Temp. characters | |||||||
| Operation Temp.(℃)2 | -40 | 125 | |||||
| Compensation Temp(℃) | -10 | 70 | |||||
| Zero Temp.error(%FS)3 | ±0.75 | ±1 | |||||
| Span Temp. error(%FS)3 | ±1 | ±1.5 | |||||
| Long term Stability | |||||||
| Zero (±%FS annual) | 0.2 | ||||||
| Span (±%FS annual) | 0.2 | ||||||
| Supply Voltage | 5 | 10 | |||||
| Input Resistance | 5.0 | 6.6 | 8.0 | ||||
| Output Resistance | 3.5 | 4.4 | 5.5 | ||||
| Insulation Resistance(100V)4 | 100MΩ | ||||||
| Fastening Torque |
Recommended | ≦50Mpa: 40Nm; ﹥50Mpa:70Nm | |||||
| Maximum | 90Nm | ||||||
| Pressure Range | 0-3.5Mpa…100Mpa | ||||||
| Pressure overload | 2X or 130Mpa whichever is less | ||||||
| Pressure burst | 5X or 130Mpa whichever is less | ||||||
| Pressure Media | Liquids and Gases compatible with 17-4PH and 304 Stainless Steel | ||||||
Remark:
1. Best fit straight line
2. Maximum temperature range for product with standard cable is -20°C to +105°C
3. Over the compensated temperature range with respect to 25°C
4. Between case and sensing element
| Model | Description | ||||||
| ACM1 | Microfused pressrue sensor | ||||||
| Code | Pressure Range | ||||||
| 3.5M | 3.5Mpa | ||||||
| 7M | 7Mpa | ||||||
| 10M | 10Mpa | ||||||
| 20M | 20Mpa | ||||||
| 35M | 35Mpa | ||||||
| 50M | 50Mpa | ||||||
| 70M | 70Mpa | ||||||
| 100M | 100Mpa | ||||||
| XX | Special | ||||||
| Code | Housing mate options | ||||||
| A | A type | ||||||
| B | B type | ||||||
| C | C type | ||||||
| D | D type | ||||||
| X | Special | ||||||
| Code | Thread of pressrue port | ||||||
| 1 | 1/4-18NPT | ||||||
| 2 | G1/4 | ||||||
| 3 | M20X1.5 | ||||||
| X | Special | ||||||
| Code | Electrical Connection | ||||||
| 1 | Connect Pins | ||||||
| 2 | Ribbon Cable(90mm as default) | ||||||
| X | Special | ||||||
| Code | Snubber | ||||||
| S | With snubber | ||||||
| Example: | |||||||
| ACM1 | 35M | C | 2 | 1 | S | ||
| 0-35Mpa | C type | G1/4 | Pins | with snubber | Model:ACM1-35M-C2-1S | ||