Introduction:

AC18C concave film ceramic pressure sensor is an ideal pressure sensing element, can be used to fit into a metal shell or directly integrate with the electronic circuit of machinery and equipment. Full temperature compensation type, to ensure that the maximum temperature drift does not exceed 0.04% FS /°C within the operating temperature range. This structure makes the pressure sensor very stable under harsh conditions. The internal sensing elements are fully protected from humidity, humidity and chemical corrosion. Not afraid of condensation, provides a typical output of 3mV/V, allowing simple signal adjustment.

Features:

* Ceramic thick film integrated piezoresistive technology
* Excellent long-term stability
* Effective temperature compensation
* Operating temperature range-40 ∽ + 135°C
* High reliability
* Complete internal protection to avoid humidity and condensation effects
* Large-scale OEM applications for all corrosive media (except hydrofluoric acid, According to IEC 61298-2)
* Small size, easy to package

Application:

* Pneumatic equipment
* Hydraulic equipment
* Medical equipment
* Air compressors
* Refrigeration systems
* Domestic small appliances
* Battery-powered equipment

Concave Film Ceramic Pressure Sensor

Pressure range 0…2 to  0…600 bar
Diameter 18 mm
Overall accuracy (linearity + hysteresis) ≤±0.3% FS [End-point linearity] Other ranges except 2bar
≤±0.5% FS [End-point linearity] 2bar
Repeatability ≤±0.1% FS
Electrical Specifications
Maximum excitation voltage 30 Vdc
Bridge impedance 11 KΩ±30%
Zero offset ≤±0.2 mV/V
Insulation resistance > 2 KV
Zero point long-term stability @20°C ±0.2% FSO, typ. (no time accumulation)
Environmental specifications
Direct contact with liquid materials 96% aluminum oxide
Operating temperature – 40 up to + 135°C
Storage temperature – 50 up to + 150°C
Temperature drift (zero position & sensitivity) Range 2bar ~ 50 bar ≤±0.03 % FS / °C [ 0°C -85°C]
≤±0.04 % FS / °C [ -40°C-0°C]/[85°C-135°C]
Range > 50 bar ≤±0.04 % FS / °C [ 0°C -85°C]
≤±0.05 % FS / °C [ -40°C-0°C]/[85°C-135°C]
Relative humidity 0-95% (non-condensing)
Sensor weight <7g
Code Range(bar) Burst pressure(bar) Full-scale output signal (mV/V)
AC18C-2 0~2 5.00 1.8 ~4.2
AC18C-5 0~5 12.50 2.2~4.2
AC18C-10 0~10 25.00 2.3~4.7
AC18C-20 0~20 50.00 2.4~4.8
AC18C-30 0~30 70.00 2.4~4.4
AC18C-40 0~40 100.00 2.4~4.4
AC18C-50 0~50 125.00 2.4~4.4
AC18C-100 0~100 200.00 2.0~3.6
AC18C-200 0~200 400.00 1.6~2.8
AC18C-400 0~400 600.00 1.6~2.8
AC18C-600 0~600 800.00 1.6~2.8

Burst pressure: It is calibrated to the burst pressure at room temperature, please consult us for the burst pressure under high and low temperature environment

Leave a Message

If you have any questions, please leave us a message and we will reply to you as soon as possible

    Please Enter Your Message


      en_USEnglish